For oceanography - and there in particular for the description of ocean currents - accurate measurements of the density of sea water are of great importance. For this purpose, measuring instruments are needed which reach an uncertainty of approx. 0.001 kg/m3 (relative 1 . 10-6).

To be able to calibrate these measuring instruments, ultra-pure water is required as a reference fluid - the density of which can now be measured with the required accuracy over a large temperature range by means of the Magnetic Flotation Method which has been further developed at PTB.

Normally, the hydrostatic weighing method is used for measuring the density of liquids. Thereby, the density of the liquid is determined by means of Archimedes' principle from the buoyancy which is experienced by a sinker that plunges into the fluid. This method has several disadvantages which become apparent especially when water is to be measured. For this method, an open fluid tank is required into which the sinker - hanging on a wire - plunges.

At the point where the wire passes through the surface of the liquid into the water, a meniscus forms which, in the case of water, is extremely difficult to be reproduced and therefore contributes significantly to the measurement uncertainty. Along the wire, a temperature gradient occurs which, too, increases the measurement uncertainty. Due to the open system, the gas content of the water is difficult to control, but it alters the density.

In order to eliminate these sources of uncertainty, an apparatus has been developed in which the wire has been replaced by a magnetic coupling. In this magnetic flotation system, a small magnet is mounted at the holder of the sinker. By means of this magnet, and with the aid of a controllable magnetic field produced by an electromagnet, the sinker is kept in a fixed position. The current needed for this purpose is a measure for the buoyancy that is experienced by the sinker.

The fluid tank can almost be shut as the liquid is linked with the outside world only via a thin pipe by means of which the pressure can be regulated. In this way, it is possible to measure also with fully degassed water.

Thanks to the fact that the above-mentioned sources of uncertainty are avoided, measurements can be carried out with a repeatability standard deviation of approx. 2 � 10-7. The total measurement uncertainty of the water density measurement therefore reaches a value below 1 � 10-6. The measurements carried out with this new apparatus could confirm to a large extent the values delivered by foreign colleagues.

However, there are still discrepancies in the temperature range around 4 C, which is of great importance especially in oceanography. Therefore, there is still a great need for further research in this field.

Related Links
Physikalisch-Technische Bundesanstalt (PTB)
Water News - Science, Technology and Politics



Memory Foam Mattress Review
Newsletters :: SpaceDaily :: SpaceWar :: TerraDaily :: Energy Daily
XML Feeds :: Space News :: Earth News :: War News :: Solar Energy News


Cameroon, China strike water deal: report
Yaounde (AFP) Dec 17, 2007
Cameroon and China have clinched an agreement to increase water production and distribution in Cameroon's economic capital Douala, the government daily Cameroon Tribune reported Monday.







  • NASA To Begin Testing Of Engine That Will Power Ares Rockets
  • Constellation Services International And Space Systems Loral Team On NASA COTS Proposal
  • NASA Selects Prime Contractor For Ares I Rocket Avionics
  • ATK Test Fires Liquid Oxygen-Methane Rocket Engine In Vacuum

  • Lightning Protection For The Next Generation Spacecraft
  • HISPASAT Chooses Arianespace To Launch The Amazonas 2 Satellite
  • Russia Tests Engine For Angara Carrier Rocket
  • United Launch Alliance Launches 2nd COSMO Satellite

  • NASA aims for early January launch
  • NASA Targets Space Shuttle Atlantis Launch For January 10
  • NASA to test faulty shuttle gauges next week
  • Daunting technical problem mars a good year for NASA

  • Whitson And Tani Complete The 100th Station Spacewalk
  • Astronauts hook up huge module to space station
  • Spacewalkers Preparing To Inspect SARJ, BGA On Tuesday
  • Columbus Launch Now No Earlier Than 2nd January

  • Russia To Launch Space Base For Missions To Moon And Mars After 2020
  • Final Preparations For First Human-Rated Spacecraft To Be Launched From Europe's Spaceport
  • Russia Soon To View Two Space Transport Projects
  • Brain Stem Cells Sensitive To Space Radiation

  • President Hu: China Joins Nations With Capability Of Deep Space Exploration
  • China's space ambitions key to nation's strength: Hu
  • Chang'e-1 Photographs Dark Side Of The Moon
  • China-Made Satellite Navigation System To Support Olympic Games

  • Honda's ASIMO robot gets smarter
  • Toyota's new robot can play the violin, help the aged
  • Humanoid teaches dentists to feel people's pain: researchers
  • Japan looks at everyday use of robots

  • The Closest Approach Of Mars In 2007
  • Rowan University Professor Seeing Red (Planet)
  • Spirit Scouts Home Plate For Safe Haven
  • Mars Orbiter Examines Lace And Lizard Skin Terrain

  • The content herein, unless otherwise known to be public domain, are Copyright Space.TV Corporation. AFP and UPI Wire Stories are copyright Agence France-Presse and United Press International. ESA Portal Reports are copyright European Space Agency. All NASA sourced material is public domain. Additional copyrights may apply in whole or part to other bona fide parties. Advertising does not imply endorsement, agreement or approval of any opinions, statements or information provided by Space.TV Corp on any Web page published or hosted by Space.TV Corp. Privacy Statement