Scanning electrochemical microscopy: Researchers position a microelectrode (grey) in the immediate vicinity of the cell. At the electrode, oxygen is converted into water (black arrow), while electrons flow through the electrode. Through cellular respiration (green arrow), the cell consumes oxygen and competes with the electrode. Additional sources of oxygen can interfere with the measurement: oxygen can diffuse from the surrounding aqueous solution into the gap between the electrode and the cell (grey arrow) or be extracted from the cell (blue arrows). The topography, i.e. the height profile of the cell, is shown on the top left; at the top right the oxygen consumption measured at the cell surface is displayed. Image courtesy Wolfgang Schuhmann.

How active a living cell is can be seen by its oxygen consumption. The method for determining this consumption has now been significantly improved by chemists in Bochum. The problem up to now was that the measuring electrode altered the oxygen consumption in the cell's environment much more than the cell itself.

"We already found that out twelve years ago," says Prof. Dr. Wolfgang Schuhmann from the Department of Analytical Chemistry at the Ruhr-Universitat. "Now we have finally managed to make the measuring electrode an spectator." Together with his team, he reports in the "International Edition" of the journal "Angewandte Chemie".

Precise positioning of the measuring electrodes
Cells need oxygen for various metabolic processes, for example to break down glucose. To measure its consumption, researchers have to detect very small signals in a large background noise.

For this they use scanning electrochemical microscopy, for which they need to position electrodes with a diameter of five micrometres or below at a distance of 200 nanometres from the cell. To this end, the RUB team has developed a special process over the last few years, with which the distance of the electrode to the cell can be precisely controlled.

Making competition to the cells with microelectrodes
Using the electrode, the researchers first generate oxygen in the aqueous environment of the cell, and then they measure how much of this oxygen the cell utilises. For this purpose, they give the electrode a certain potential at the beginning.

This has the effect that electrons are extracted from water in the cell environment under formation of oxygen. The cell can use the oxygen for its metabolism; however, at the same time, the microelectrode applied by the researchers competes against it.

They change the potential at the electrode so that the reaction reverses: oxygen is now converted to water. The scientists use the electrode to measure the electrons flowing and thus obtain a measure of the oxygen consumption in the local environment.

The more oxygen the cell uses for its metabolism, the less oxygen is left for the current-generating reaction at the electrode. Thus, the lower the current flow measured, the greater the activity of the cell. This method is termed the redox competition mode.

Rapid measurement
In the methods used so far, the oxygen consumption caused by the electrode was significantly higher than that of the cell.

"The measurement itself thus caused a stronger local change in the oxygen concentration than the cell metabolism," explains Prof. Schuhmann.

It was essential to measure the activity of the cell very quickly after the oxygen was generated at the microelectrode, i.e. after twenty milliseconds. If you wait longer, the electrode deprives the cell of oxygen instead of using the oxygen from the environment that the researchers had artificially created in advance.

Three factors were therefore crucial for the success of the Bochum method: the highly accurate position of the electrodes, the redox competition mode and the rapid measuring time.

M. Nebel, S. Grutzke, N. Diab, A. Schulte, W. Schuhmann (2013): Visualization of oxygen consumption of single living cells by scanning electrochemical microscopy: the influence of the faradaic tip reaction, Angewandte Chemie International Edition, DOI: 10.1002/anie.201301098

.


Related Links
Ruhr-University Bochum
Darwin Today At TerraDaily.com






Comment on this article via your Facebook, Yahoo, AOL, Hotmail login.

Share this article via these popular social media networks
del.icio.usdel.icio.us DiggDigg RedditReddit GoogleGoogle








FLORA AND FAUNA
Climate change will cause widespread global-scale loss of common plants and animals
Norwich, UK (SPX) May 22, 2013
More than half of common plants and one third of the animals could see a dramatic decline this century due to climate change - according to research from the University of East Anglia. Research published in the journal Nature Climate Change looked at 50,000 globally widespread and common species and found that more than one half of the plants and one third of the animals will lose more tha ... read more


FLORA AND FAUNA
O3b Networks' initial satellite is fueled for Arianespace's upcoming Soyuz launch from the Spaceport

Ariane Flight VA214's launch vehicle marks a preparation milestone

ILS Proton Successfully Launches EUTELSAT 3D for Eutelsat

Russia's Proton-M Spacecraft Set to Orbit French Satellite

FLORA AND FAUNA
NASA Mars Rover Curiosity Drills Second Rock Target

Mars Icebreaker Life Mission

Nine-Year-Old Mars Rover Passes 40-Year-Old Record

NASA Probe Counts Space Rock Impacts on Mars

FLORA AND FAUNA
Bright Explosion on the Moon

NASA says meteor impact on the moon glowed like a star

Where on Earth did the moon's water come from

Water on moon, Earth have a common source

FLORA AND FAUNA
'Vulcan' wins Pluto moon name vote

Public to vote on names for Pluto moons

The PI's Perspective: The Seven-Year Itch

New Horizons Gets a New Year's Workout

FLORA AND FAUNA
Critical Kepler Reaction Wheel Fails: Mission End In Sight

Sifting Through the Atmosphere's of Far-Off Worlds

New Method of Finding Planets Scores its First Discovery

Team Takes Part in Discovering New Planet

FLORA AND FAUNA
ATK Hoping Tp Clean Up Rocketscience

Sierra Nevada Corporation Dream Chaser Testing Begins at NASA Dryden, Langley

A-1 Test Stand Houses First Full Engine in Nearly a Decade

Space tourism won't hurt environment: Branson

FLORA AND FAUNA
China launches communications satellite

On Course for Shenzhou 10

Yuanwang III, VI depart for space-tracking missions

Shenzhou's Shadow Crew

FLORA AND FAUNA
Asteroid 1998 QE2 To Sail Past Earth Nine Times Larger Than Cruise Ship

NASA's Asteroid Sample Return Mission Moves into Development

Dawn On Route From Vesta to Ceres

Nine-Year-Old Names Target of UA-led NASA Mission




The content herein, unless otherwise known to be public domain, are Copyright 1995-2014 - Space Media Network. AFP, UPI and IANS news wire stories are copyright Agence France-Presse, United Press International and Indo-Asia News Service. ESA Portal Reports are copyright European Space Agency. All NASA sourced material is public domain. Additional copyrights may apply in whole or part to other bona fide parties. Advertising does not imply endorsement,agreement or approval of any opinions, statements or information provided by Space Media Network on any Web page published or hosted by Space Media Network. Privacy Statement