Hip implant for long-term use
by Staff Writers
Stuttgart, Germany (SPX) May 11, 2012


Hip implant for long-term use.

Hip replacement is one of the most frequent operations carried out in Germany. Each year, doctors implant some 200,000 artificial hip joints. Often the artificial hips need to be replaced just ten years later. In the future, a new implant currently being developed using high technology materials could help prevent premature revision surgeries.

Thanks to artificial hips, people with irreparable damage to the joint have been able to lead active, pain-free lives for the past 50 years. Still, some hip replacements do not function completely as intended, and metal-on-metal implants in particular, demand accurate positioning in surgery and implants positioned non optimally are often susceptible to premature failure notably in small female patients.

Physicians are even calling for a prohibition on the use of artificial joints made of cobalt-chromium alloys in which the joint's metal ball rubs against its metal socket whenever the wearer walks. Poorly designed or positioned metal on metal implants can lead to higher wear rates and this releases elevated cobalt-chromium ion levels that spread out through the blood and lymph, potentially damaging organs and triggering inflammation.

Metal ions are also suspected carcinogens. Because these hip replacements are so robust, however, to date they have often been implanted in young, active patients.

A metal-free composite
Researchers at the Fraunhofer Institute for Manufacturing Engineering and Automation IPA in Stuttgart, partnering in an international team on an EC-funded project entitled "ENDURE" (Enhanced Durability Resurfacing Endoprosthesis), have now developed a new kind of hip implant that, unlike the conventional counterpart implants on the market today, provide a metal-free solution and bone-like elasticity.

This is the result of a metal-free, high-tech composite: The hip socket is made of carbon fibre-reinforced PEEK - a high-strength, wear resistant, biocompatible polymer composite. For the femoral head, ceramic was used.

In addition to this, a hydroxylapatite coating at the interface to the bone helps ensure that the bone tissue will fuse thoroughly with the surface structure of the implant.

"The cobalt-chromium implants in use to date are very rigid, and the load transfer to the bone is non-optimal leading to potential adverse bone adaptation. Thanks to the new combination of materials, the transmission of force through the PEEK hip socket to the pelvic bone is modeled on natural conditions. And there are no metal ions released," notes IPA engineer Jasmin Hipp.

The researcher and her team were able to confirm the good wear resistance in initial tests of the new hip replacement using a robot that simulated various series of movements such as walking or climbing and descending stairs. The experiments used a prototype of the implant.

Tiny pins protect bone tissue
The ENDURE implants follow the bone-preserving principle of hip resurfacing: they are thin-walled shells which replace the bearing surface of the joint articulation alone, instead of employing large metal stems for support, which require a substantial volume of bone to be removed. Researchers have also redesigned the way the prosthesis is mechanically attached to the bone.

Without cement, and using a press-fit and an integral scaffold-type structure on the surfaces of the implant that contact the bone, the hemispherical ball and socket are tapped onto the prepared femoral head and into the acetabulum - the natural, concave surface of the pelvis - and anchored in place.

To ensure the best possible positioning of the artificial hip, the researchers at IPA have developed a size-scalable tool that attaches the implant to standard surgical instruments, enabling implantation, re-alignment and removal.

The tool can be discarded after a single use - like a disposable surgical glove. The challenge is to attach instruments to the very thin-walled cup implant, with sufficient strength for implant repositioning. The instrument features a smart collet pin combination allowing strong, quick, single-position attachment and detachment by the surgeon. The scientists have already submitted a patent application for the tool.

A team of physicians at the University of Newcastle have demonstrated in operations performed on cadavers, the new hip can be set in place and, if necessary, removed without any difficulties. Meanwhile, the preclinical studies have been completed, and final development work is being planned to allow clinical studies to commence. Partners in the EU-funded project are Aurora Medical, Medicoat, Hunt Developments, Ala Ortho, CeramTec, Invibio, Biomatech and the Universities of Gothenburg and Southampton.

Research News - May 2012.pdf [ PDF 0.39MB ]

.


Related Links
Fraunhofer Institute
Hospital and Medical News at InternDaily.com






Comment on this article via your Facebook, Yahoo, AOL, Hotmail login.

Share this article via these popular social media networks
del.icio.usdel.icio.us DiggDigg RedditReddit GoogleGoogle








INTERN DAILY
China to probe 'dead baby' pills claims
Shanghai (AFP) May 9, 2012
China has pledged to investigate allegations that capsules containing the powdered flesh of dead babies are being produced on its soil and smuggled into South Korea. The gruesome practice came to light Sunday when Korea Customs said it had uncovered multiple attempts to illegally import, in total, more than 17,000 of the capsules in travellers' luggage or by mail. The pills are said to b ... read more


INTERN DAILY
A Soyuz takes shape in French Guiana for the next dual Galileo satellite launch

SpaceX boss admits sleep elusive before ISS launch

Air Force launches 2nd advanced satellite

A trio of Ariane 5 launchers are now at the Spaceport

INTERN DAILY
NASA Spacecraft Detects Changes in Martian Sand Dunes

Prof Active In Mission To Determine Climate Change And Life On Mars

Technology developed at Caltech measures Martian sand movement

Russia could join U.S. in Mars mission

INTERN DAILY
Perigee "Super Moon" On May 5-6

India's second moon mission Chandrayaan-2 to wait

European Google Lunar X Prize Teams Call For Science Payloads

Russia to Send Manned Mission to Moon by 2030

INTERN DAILY
Beyond Pluto And Exploring the Kuiper Belt

Uranus auroras glimpsed from Earth

Herschel images extrasolar analogue of the Kuiper Belt

New Horizons on Approach: 22 AU Down, Just 10 to Go

INTERN DAILY
Unseen planet revealed by its gravity

Ultra-cool companion helps reveal giant planets

NASA's Spitzer Sees the Light of Alien 'Super Earth'

Looking for Earths by looking for Jupiters

INTERN DAILY
Aerojet's AJ26 Flight Engine Successfully Hot-Fire Tested for Orbital's Antares Rocket

Russia Develops Revolutionary Ammonia Rocket Engine

Dragon Expected to Set Historic Course

Aerojet Completes Testing of Next-Generation Exploration Thruster

INTERN DAILY
China's Lunar Docking

Shenzhou-9 may take female astronaut to space

China to launch 100 satellites during 2011-15

Three for Tiangong

INTERN DAILY
NASA Dawn Mission Reveals Secrets of Large Asteroid

Asteroid collision that spawned Vesta's asteroid family occurred more recently than thought

Vesta - a planet-like asteroid

You're beautiful, Vesta




The content herein, unless otherwise known to be public domain, are Copyright 1995-2014 - Space Media Network. AFP, UPI and IANS news wire stories are copyright Agence France-Presse, United Press International and Indo-Asia News Service. ESA Portal Reports are copyright European Space Agency. All NASA sourced material is public domain. Additional copyrights may apply in whole or part to other bona fide parties. Advertising does not imply endorsement,agreement or approval of any opinions, statements or information provided by Space Media Network on any Web page published or hosted by Space Media Network. Privacy Statement