Engineered biomaterial could improve success of medical implants
By Michelle Ma for UW News
Seattle WA (SPX) May 22, 2013


These images show differences in collagen build-up in two tissue samples. Collagen is labeled in blue. The left image shows a thick collagen wall forming in the presence of a material that's widely used for implantable devices. In contrast, collagen in the right image is more evenly dispersed in the tissue after the UW-engineered hydrogel has been implanted.

It's a familiar scenario - a patient receives a medical implant and days later, the body attacks the artificial valve or device, causing complications to an already compromised system.

Expensive, state-of-the-art medical devices and surgeries often are thwarted by the body's natural response to attack something in the tissue that appears foreign. Now, University of Washington engineers have demonstrated in mice a way to prevent this sort of response. Their findings were published online this week in the journal Nature Biotechnology.

The UW researchers created a synthetic substance that fully resists the body's natural attack response to foreign objects. Medical devices such as artificial heart valves, prostheses and breast implants could be coated with this polymer to prevent the body from rejecting an implanted object.

"It has applications for so many different medical implants, because we literally put hundreds of devices into the body," said Buddy Ratner, co-author and a UW professor of bioengineering and of chemical engineering. "We couldn't achieve this level of excellence in healing before we had this synthetic hydrogel."

The body's biological response to implanted devices - medical technologies that often cost millions to develop - has frustrated experts for years. After an implant, the body usually creates a protein wall around the medical device, cutting it off from the rest of the body. Scientists call this barrier a collagen capsule. Collagen is a protein that's naturally found in our bodies, particularly in connective tissues such as tendons and ligaments.

If a device such as an artificial valve or an electrode sensor is blocked off from the rest of the body, it usually fails to work. Physicians and scientists have tried to minimize this, but they haven't been able to eliminate it, Ratner said.

Ratner's collaborator and co-author Shaoyi Jiang, a UW professor of chemical engineering, and his team implanted the polymer substance into the bodies of mice. The substance is known as a hydrogel, a flexible biomedical material swollen with water.

It's made from a polymer that has both a positive and negative charge, which serves to deflect all proteins from sticking to its surface. Scientists have found that proteins appearing on the surface of a medical implant are the first signs that a larger collagen wall will form.

After three months, Jiang and his team found that collagen was loosely and evenly distributed in the tissue around the polymer, suggesting that the mice bodies didn't even detect the polymer's presence.

For humans, the first three weeks after an implant are the most critical, because by then the body will show signs of isolating the implant by building a collagen wall. If this hasn't happened in the first several weeks, it's likely the body won't default to an attack response toward the object.

"Scientists have tried many materials, and with no exception, this is the first non-porous, synthetic substance demonstrating that no collagen capsule forms, which could have positive implications for implantable materials, tissue scaffolds and medical devices," Jiang said.

UW researchers and others have worked for nearly 20 years to find a way to help the body accept implants. In 1996, the National Science Foundation-funded UW Engineered Biomaterials (UWEB) research center opened at the UW, with Ratner serving as director. Since that time, researchers have been trying to make a material that is invisible to the body's immune response and could eliminate the body's negative reaction to medical implants.

Now, nearly two decades years later, engineers have found the "perfect" substance, Ratner said.

"This hydrogel is not just pretty good, it's exceptional," he said.

The UW researchers plan to test this in humans, likely by working with manufacturers to coat an implantable device with the polymer, then measure its ability to ward off protein build-up.

The research was funded by the U.S. Office of Naval Research, UWEB and the UW Department of Chemical Engineering. The findings were published online this week in the journal Nature Biotechnology.

.


Related Links
University of Washington
Hospital and Medical News at InternDaily.com






Comment on this article via your Facebook, Yahoo, AOL, Hotmail login.

Share this article via these popular social media networks
del.icio.usdel.icio.us DiggDigg RedditReddit GoogleGoogle








INTERN DAILY
China's Li to pay tribute to heroic Indian doctor
Mumbai (AFP) May 21, 2013
China's premier will pay his respects Tuesday to the family of an Indian doctor who died treating Chinese troops more than 70 years ago, becoming a rare symbol of friendship between the two nations. Li Keqiang, like Chinese leaders before him, will take time out of his busy India visit to meet relatives of Dwarkanath Kotnis, who provided emergency medical aid for four years during the Sino-J ... read more


INTERN DAILY
O3b Networks' initial satellite is fueled for Arianespace's upcoming Soyuz launch from the Spaceport

Ariane Flight VA214's launch vehicle marks a preparation milestone

ILS Proton Successfully Launches EUTELSAT 3D for Eutelsat

Russia's Proton-M Spacecraft Set to Orbit French Satellite

INTERN DAILY
NASA Mars Rover Curiosity Drills Second Rock Target

Mars Icebreaker Life Mission

Nine-Year-Old Mars Rover Passes 40-Year-Old Record

NASA Probe Counts Space Rock Impacts on Mars

INTERN DAILY
Bright Explosion on the Moon

NASA says meteor impact on the moon glowed like a star

Where on Earth did the moon's water come from

Water on moon, Earth have a common source

INTERN DAILY
'Vulcan' wins Pluto moon name vote

Public to vote on names for Pluto moons

The PI's Perspective: The Seven-Year Itch

New Horizons Gets a New Year's Workout

INTERN DAILY
Critical Kepler Reaction Wheel Fails: Mission End In Sight

Sifting Through the Atmosphere's of Far-Off Worlds

New Method of Finding Planets Scores its First Discovery

Team Takes Part in Discovering New Planet

INTERN DAILY
ATK Hoping Tp Clean Up Rocketscience

Sierra Nevada Corporation Dream Chaser Testing Begins at NASA Dryden, Langley

A-1 Test Stand Houses First Full Engine in Nearly a Decade

Space tourism won't hurt environment: Branson

INTERN DAILY
China launches communications satellite

On Course for Shenzhou 10

Yuanwang III, VI depart for space-tracking missions

Shenzhou's Shadow Crew

INTERN DAILY
Asteroid 1998 QE2 To Sail Past Earth Nine Times Larger Than Cruise Ship

NASA's Asteroid Sample Return Mission Moves into Development

Dawn On Route From Vesta to Ceres

Nine-Year-Old Names Target of UA-led NASA Mission




The content herein, unless otherwise known to be public domain, are Copyright 1995-2014 - Space Media Network. AFP, UPI and IANS news wire stories are copyright Agence France-Presse, United Press International and Indo-Asia News Service. ESA Portal Reports are copyright European Space Agency. All NASA sourced material is public domain. Additional copyrights may apply in whole or part to other bona fide parties. Advertising does not imply endorsement,agreement or approval of any opinions, statements or information provided by Space Media Network on any Web page published or hosted by Space Media Network. Privacy Statement